Skip to content
Research use only — not for human or veterinary use | Lawrenceville, GA, USA | 21+ verification requiredResearch use only · 21+
Free tracked shipping on every order over $350

August 12, 2026

How to read a peptide Certificate of Analysis

A certificate of analysis is the only part of a peptide supplier’s marketing that can be checked. This is how to check it — ours or anyone else’s.

Every supplier in this category says the same four words: third-party lab tested. The phrase has been repeated so often that it has stopped carrying information. What separates one supplier from another is not whether they say it, but whether the document behind the claim survives being read carefully.

Most buyers never open the certificate. Of those who do, most look at one number — the purity figure — and stop. That number is the least informative thing on the page.

Start with the lot number, not the purity

The first thing to check on any certificate is whether the lot number at the top matches the lot printed on the vial in front of you. A certificate that belongs to a different batch tells you nothing about your material.

This is the question that does the most work, and the one most certificates quietly fail.

A purity figure on a website is a claim about a company. A purity figure tied to a lot number, with the certificate behind it, is a claim about the specific material you were sent. Those are not the same statement, and the gap between them is where most of the dishonesty in this category lives.

The failure mode is simple. A supplier tests one lot — perhaps genuinely, perhaps well — publishes that certificate, and then keeps showing it against every subsequent lot for two years. Nothing on the page is false. The document is real, the lab is real, the number is real. It just has nothing to do with the vial on your bench.

If a supplier cannot produce a certificate for your specific lot, that is the answer to your question.

Is there a laboratory name on it?

This filter eliminates more certificates than any other.

A certificate of analysis should name the laboratory that performed the assay, and that laboratory should be somebody other than the company selling you the material. If the only name on the document is the vendor’s own, you are not holding a third-party certificate. You are holding a self-report with a border around it.

Self-reports are not automatically worthless — a supplier with its own HPLC and an honest technician can produce perfectly good data. But it is a different category of evidence, and a supplier that blurs the line between the two has told you something about how it handles other ambiguities.

Check that the laboratory exists. A name, a city, and ideally a website. If the lab publishes reports under its own identifier, better still: you can ask them directly whether report number X is real.

The HPLC trace

The purity figure is a summary. The chromatogram is the evidence it was summarised from, and it is much harder to fake convincingly.

Reversed-phase HPLC separates compounds by how strongly they adhere to a hydrophobic column under a gradient of increasing solvent. Purity is reported as the area of the main peak as a percentage of all peak area — a statement about proportion, measured by UV absorbance, among things that came off the column. Each of those qualifiers is a limit.

You do not need to be an analytical chemist to get value from looking at the trace. Three things are visible to anyone:

The main peak should be tall, narrow, and roughly symmetrical. A broad or badly tailing peak suggests the material is heterogeneous in a way the integration may not have captured.

The baseline should be flat and quiet. A noisy baseline makes small impurity peaks disappear into the noise, which inflates the purity figure without anyone having to lie.

The axes should be labelled, with a gradient description and a run time. A chromatogram without them is a picture of a chromatogram rather than a chromatogram.

Be suspicious of a trace that is perfectly smooth with a single needle-thin peak and nothing else. Real separations have texture.

Mass spectrometry confirms identity, not quality

Purity and identity are different properties, and one test cannot establish both.

HPLC tells you how much of the material is a single compound. It has no opinion about which compound. Mass spectrometry measures mass-to-charge ratio and compares the observed mass against the theoretical mass calculated from the sequence — and that is what tells you whether the single compound is the one you ordered.

A certificate with purity but no identity data is telling you the vial contains 99% of something. A highly pure wrong peptide passes an HPLC purity test without difficulty.

When observed and theoretical masses differ, the size of the gap is often diagnostic:

  • +18 Da — a water molecule, often incomplete cyclisation or hydrolysis
  • +22 Da — a sodium adduct, usually a handling artefact
  • +16 Da — oxidation, most commonly at methionine or tryptophan
  • −17 Da — loss of ammonia, frequently from a terminal glutamine
  • A gap matching one residue’s mass — a deletion sequence, meaning an amino acid is missing from the chain

That last one matters more than its size suggests. Deletion sequences are common synthesis by-products, chemically very similar to the target, and they frequently co-elute with it — so HPLC may not resolve them into a separate peak at all. A deletion impurity can hide comfortably inside a 99% purity figure. Mass spectrometry is what catches it.

Endotoxin and moisture

Beyond purity and identity, a thorough certificate reports several things that suppliers commonly economise on, and whose absence is rarely announced:

  • Water content by Karl Fischer titration. Lyophilised material is hygroscopic, and residual moisture drives hydrolysis in storage.
  • Peptide content as distinct from net weight. UV at 214nm does not see salts, water or counter-ions, so a vial can be 99% pure by HPLC and still be substantially non-peptide by mass.
  • Counter-ion, usually acetate or trifluoroacetate, with its proportion.
  • Endotoxin, where the intended work is sensitive to it — bacterial endotoxin confounds a wide range of cell-based assays at concentrations far below anything visible.

None of these are mandatory. Their presence tells you the supplier bought a real analytical package rather than the cheapest line on the laboratory’s menu.

Does the arithmetic hold?

Two quick checks catch a surprising amount.

Observed against theoretical mass. The certificate should state both, and any difference should be explicable by the table above. A gap of several hundred daltons, unexplained, is a different compound.

Purity against the impurity table, where one is given. If the main peak is reported as 99.2% and the listed impurities sum to 3%, something has been integrated twice or transcribed wrong. It may be an honest error. It is still an error on a document whose only purpose is to be accurate.

Is it dated?

A certificate should carry the date the analysis was performed, not merely the date the PDF was generated. Those are different, and the gap is occasionally instructive.

Peptides degrade at rates that depend heavily on sequence and storage. A certificate issued at synthesis describes the material as it was then — the right document to ask for, but a statement about the past. A two-year-old certificate for material stored at room temperature is describing a different substance from the one you will open.

Three reasons to reject a lot

Most certificates are fine. These three are not, and none of them require equipment to spot:

1. The lot number does not match your vial. Whatever else the document says, it is describing someone else’s material. This is not a technicality and it is not negotiable.

2. There is no identity data. Purity alone cannot tell you what is in the vial. A certificate reporting 99.4% and nothing else has told you the material is homogeneous, which is a different claim from correct.

3. The only name on the certificate is the seller’s. It may well be accurate. It is still a self-report, and it should be weighed as one.

What this adds up to

Seven checks, none requiring equipment:

  1. A lot number that matches your vial
  2. A named third-party laboratory, not the vendor
  3. A chromatogram that looks like a real separation
  4. Identity data as well as purity
  5. Moisture, peptide content and counter-ion reported
  6. Arithmetic that holds between the figures
  7. A date on the analysis

A certificate passing all seven is doing its job. One failing the first two is not evidence of anything, however impressive the number at the top.

We publish certificates against lot numbers because the alternative — a figure on a webpage with nothing underneath it — is a claim we would not accept from a supplier ourselves. If you ever find one of ours that fails a check on this list, tell us and we will either explain it or fix it.

Research use only. All materials referenced here are supplied for in-vitro laboratory research. Not for human or veterinary use, and not for diagnostic or therapeutic use of any kind.